Buntheng Ly1, Nicolas Cedilnik2, Mihaela Pop2
1Pôle Sciences de l'Imagerie, Institut Hospitalo-Universitaire Liryc, Bordeaux, France.
Objectives:
Accurate parameterisation of cardiac patient-specific models is a major challenge. Here we aimed to test the feasibility of an optimised multimodal personalisation framework that combines structural information from computed tomography (CT) and 12-lead electrocardiograms (ECGs) features, for high-fidelity simulations of ventricular tachycardia (VT).
Methods:
We studied a small cohort of six patients who had CT images and sinus-rhythm 12-lead ECGs available prior to VT ablation. The CT images were used to construct patient-specific biventricular simulation domains and to estimate ECG lead positions. We implemented a graphics processing unit-based computational pipeline and a two-stage optimisation framework consisting of: (i) an early activation onset estimation; and, (ii) the optimisation of conductivity parameter. For validation, the simulation outcomes were compared to clinical VT patterns and cycle lengths.
Results:
Following early onset estimations, simulated 12-lead ECG signals achieved a mean Q wave, R wave, and S wave (QRS) peak accuracy. Using the optimised parameters, average QRS duration error was reduced to ms, compared to ms for baseline parameters. Notably, in four patients with available electro-anatomical VT maps, simulations reproduced the clinical VT patterns and cycle length closer to recordings than those obtained with baseline parameterisation.
Conclusion:
Our pilot study demonstrates the feasibility of a robust electrophysiology modelling framework able to perform multimodal personalisation by integrating sinus-rhythm ECGs and cardiac CT images for VT simulations with tractable computational time, paving the way for its clinical translation and a less invasive scar-related VT risk assessment.