A pressure pulse wave sensor inspired by light-reflecting skin structures in atherinid fish
Related Experiment Video
Updated: Nov 7, 2026

Anesthesia-free Heartbeat Measurements in Freely Moving Zebrafish
Published on: April 18, 2025
1Hiroshima University, 1-4-2 Kagamiyama, Higashihiroshima, Hiroshima, 739-8527, Japan.
Abstract:
The human dermis and epidermis provide inspiration for the development of next-generation wearable devices for on-skin sensing. The dermis contains complex microvascular and lymphatic networks that are essential for tissue homeostasis; however, real-time visualization of dermal microfluid dynamics in vivo remains technically challenging. Here, I report that three species of Atherinidae exhibit rapid flashing ("twinkling") spots on their skin that function as optical reporters of dermal microcirculation. Spatiotemporal analyses reveal that fluid-pressure fluctuations associated with circulatory networks adjacent to chromatophore complexes are accompanied by rapid tilting of guanine platelets within iridophores. These platelets are organized into a honeycomb-like membrane structure, enabling coordinated platelet motion to modulate reflected light intensity. A prototype surface light-reflection pressure sensor patch containing guanine platelets demonstrated the conversion of applied fluid-pressure pulses into optical signals, suggesting potential applications in noninvasive physiological pulse waves monitoring. These findings reveal a previously unrecognized biological mechano-optical transduction mechanism and provide a biomimetic framework for visualizing dermal microfluid dynamics and developing wearable optical biosensing technologies.
Related Concept Videos
Sound as Pressure Waves
The pressure fluctuation depends on the difference in displacements between the successive points in the...
Channel Rhodopsins
Rhodopsins belong to the family of cell surface proteins called G-protein coupled receptors,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pressure Gauges
Pulse
The pulse serves as a clinical indicator...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...