Objective:
99mTc-PYP SPECT/CT imaging is used for diagnosis of transthyretin cardiac amyloidosis (ATTR-CA). The calculation of quantitative metrics allows assessment of the myocardial amyloid burden and supports therapy response evaluations. This study explores the implementation of reliable metrics and the validation of activity quantification methods in a multicentre study.
Methods:
As part of the IAEA Transthyretin Amyloid Cardiomyopathy (iTAC) project, a multicentre phantom study was conducted at 10 institutions using 12 hybrid SPECT/CT systems. Standardized acquisitions consistent with clinical protocols were used to compute the activity calibration factors (ACF). Absolute activity verifications were based on cardiac insert measurements with known activity distributions. Multiple reconstruction/quantification approaches (RecMethod) were evaluated, including the institution method (SiteProc) and four alternative ones; results of the computed activity were compared with the true activity meter measurements. Accuracy was assessed using RecMethod-to-True activity ratios, summarized by median, interquartile range (IQR) and coefficient of variation (CV).
Results:
Most institution ACF values (ACFSiteProc) ranged 75-105 cps/MBq and were consistent with reference CoreLab estimates. Agreement between ACFSiteProc and reference CoreLab values showed a median ratio of 99.6 %, IQR 5.8 %, and CV 9.4 %, indicating no systematic bias. For activity quantification, median RecMethod-to-True ratios were 100.1 % for the SiteProc reconstructions and 97.8 %, 94.1 %, 95.6 % and 96.0 % for the alternatives.
Conclusion:
The evaluated quantification methods demonstrated good median accuracy across institutions providing reliable activity estimates, essential for a robust implementation of quantitative metrics for ATTR-CA. The obtained inter-site variability indicates that precision remains a challenge at the multicentre quantitative imaging studies.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)