Benchmarking Protein-Ligand Cofolding Models: Correct Ligand Placement Is Decoupled From Accurate Protein Conformation
Related Experiment Video
Updated: Nov 10, 2026

Modeling Ligands into Maps Derived from Electron Cryomicroscopy
Published on: July 19, 2024
Leon Obendorf1, Niklas Piet Doering2, Petra Knaus1
1Department of Biology, Chemistry and Pharmacy, Institute of Biochemistry, Signal Transduction Group, Freie Universität Berlin, Thielallee 64, Berlin14195, Germany.
Abstract:
AI-driven cofolding models have become central tools for predicting protein-ligand complexes, yet it remains unclear whether the resulting structures recover the correct protein conformation or merely place the ligand plausibly within an otherwise mispredicted fold. Here, we benchmark four state-of-the-art cofolding models, AlphaFold3, RoseTTAFold3, Boltz-2, and Chai-1, and show that correct ligand placement is systematically decoupled from accurate prediction of the surrounding protein conformation. As test systems, we use kinases and Class A G protein-coupled receptors (GPCRs), families whose pharmacology depends on well-defined conformational states. To enable a prospective assessment, we evaluate complexes released after the training cutoffs of all tested models, together with one earlier nucleotide-bound structure as a control. We find that state-defining structural features, including kinase activation-loop, DFG/DYG geometries, and GPCR intracellular conformations such as ICL3, are frequently mispredicted even when ligand root-mean-square deviation (RMSD) is low. Cofolding adaptively remodels the orthosteric pocket around the bound ligand, but this local adaptation rarely propagates to the correct global conformation. Incorporating state-annotated templates and filtered multiple sequence alignments (MSAs) improves conformational recovery in some cases but has little effect in others, and model confidence metrics correlate with small-molecule placement but cannot report whether the local pocket geometry was recovered. Furthermore, while orthosteric ligand placement is generally reliable, the single allosteric complex in our set is misplaced by all models, even under explicit guidance. These results identify conformational decoupling as a fundamental limitation of current cofolding approaches across the systems evaluated, with direct implications for state-selective and structure-based drug design.
Related Concept Videos
Ligand Binding Sites
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
Ligand Binding Sites
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
Conserved Binding Sites
Binding sites are often located in large pockets, and if their location on a protein’s surface is unknown, it can be predicted using various approaches. The energetic method computationally analyses the...
The Equilibrium Binding Constant and Binding Strength
Ligand Binding and Linkage
Ligand Binding and Linkage

