Surface contouring of reflective and diffuse samples using dual-angle digital holographic shear interferometry
Related Experiment Video
Updated: Nov 12, 2026

Digital Inline Holographic Microscopy (DIHM) of Weakly-scattering Subjects
Published on: February 8, 2014
Sevda Mamaghani1, Konstantinos Falaggis1
1Department of Mechanical Engineering and Engineering Sciences, University of North Carolina at Charlotte, Charlotte, North Carolina 28223, USA.
Abstract:
In this work, a grating-based dual-angle digital holographic shear interferometry system is presented for generating synthetic wavelengths and extending the measurable height range. A geometric-phase (GP) grating and mirror configuration generates laterally sheared wavefronts at multiple shear orientations, while a polarization camera enables simultaneous phase-shifted intensity acquisition. Measurements are performed at two illumination angles, and the reconstructed complex wavefields are combined to obtain a synthetic phase distribution whose sensitivity is determined by the angular separation between the two measurements. The system was experimentally evaluated using standard step-height artifacts and surface features on both reflective and diffuse samples. Step-height measurements demonstrated the dependence of measurement performance on the selected synthetic wavelength. An analytical uncertainty analysis identified the illumination angle as a significant contributor to the overall measurement uncertainty, emphasizing the importance of system calibration using a standard artifact. Temporal repeatability was also evaluated through repeated measurements. The results demonstrate the capability of grating-based dual-angle digital holographic shear interferometry for quantitative three-dimensional surface reconstruction while maintaining a compact common-path configuration.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...