Potential Airborne Particulate Matter (PM) Exposures for Firefighters Working Outside Live-Fire Training Structures
Related Experiment Video
Updated: Nov 12, 2026

Aggravation of Myocardial Ischemia upon Particulate Matter Exposure in Atherosclerosis Animal Model
Published on: December 10, 2021
Gavin P Horn1, Keith Stakes1, Danielle L Neumann2
1Fire Safety Research Institute, UL Research Institutes, Columbia, USA.
Abstract:
Firefighting instructors and students may be exposed to fire effluent, including particulate matter (PM), during live-fire training. PM exposure risks may increase while preparing scenarios, staging materials and/or instructing/debriefing when respirators are often removed while operating outside of live-fire training structures. Exposure to large quantities of airborne PM has been recognized as harmful to human health. To protect instructors' and students' health, several control measures have been proposed, including incorporating different training fuels (substitution control), changing locations where instructors and students stage (administrative control) or wearing respiratory protection even when outdoors (PPE control). Stationary, time-resolved, optical real-time PM area air measurements were collected from outside two different live-fire training structures, including a single-story structure used for fire behavior training ("Fire Behavior Lab", incorporating 5 different training fuels) and a two-story structure made from concrete used for tactical training ("Multicompartment Live-Fire Training Structure", incorporating 3 different training fuels). In the Fire Behavior Lab, where fuels are mounted on the ceiling with limited ventilation (which can reduce air entrainment), fuel load had a limited impact on exterior PM concentrations, but location of the instructor (upwind from structure, moving farther away from structure) reduced the exposure hazard. For the Multicompartment Live-Fire Training Structure, different fuel loads had a more notable impact on training fire environments within the structure as well as PM concentrations outside the structure. In particular, high PM concentrations were found on the second floor, and in some situations, fire instructors may have limited ability to relocate when operating outside of elevated floors. In these cases, procedures may need to be implemented to provide reserve air supplies to these locations or rotate in new personnel to ensure proper respiratory protection for the duration of the training exercise.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Flame Photometry: Overview
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Personal Protective Equipment
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
