A novel needle insertion technique for electromyography targeting the flexor digitorum profundus (Digits 2 and 3): A cadaveric validation study
Related Experiment Video
Updated: Nov 12, 2026

Functional and Physiological Methods of Evaluating Median Nerve Regeneration in the Rat
Published on: April 18, 2020
Hong Bum Park1, Se Ryeon Lee2, Jun Yeon Lee1
1Department of Physical Medicine and Rehabilitation, College of Medicine, Korea University, Ansan, Republic of Korea.
Abstract:
The flexor digitorum profundus (FDP) muscle plays a crucial role in finger flexion and is innervated by the anterior interosseous and ulnar nerves. Electromyographic evaluation of the FDP is essential in diagnosing neuromuscular disorders but carries a risk of neurovascular injury due to the complexity of accurate needle placement. This study aimed to evaluate the anatomical feasibility of a landmark-based needle insertion technique for the index- and middle-finger portions of the FDP in fresh cadaveric specimens by assessing targeting accuracy and the distances from the insertion point to the median nerve and ulnar artery. A cadaveric study was conducted using 21 upper limbs from 11 specimens. Needles were inserted into FDP 1 (digit 2) and FDP 2 (digit 3), using the palmaris longus tendon as a key anatomical landmark. India ink injections were performed at the needle tip to verify correct placement relative to neurovascular structures. The accuracy of placement, distances from the median nerve and ulnar artery, and muscle widths were measured. Anatomical targeting was successful for FDP 1 (digit 2) in 19 of 21 limbs (90.5%) and for FDP 2 (digit 3) in 17 of 21 limbs (81%). The median horizontal distances from the needle insertion point to the median nerve and ulnar artery were 7.0 mm and 9.5 mm, respectively, providing anatomical reference data for needle placement. The median muscle widths were 8.8 mm for FDP 1 and 9.4 mm for FDP 2. These findings support the feasibility of landmark-based needle placement in the FDP, with a high anatomical targeting rate for FDP 1. This anatomical landmark-based technique may provide a useful option for electromyographic evaluation of the FDP, particularly FDP 1, when real-time imaging is unavailable. However, FDP 2 showed lower targeting accuracy. Further clinical studies are needed to evaluate the safety and practicality of this technique in patients.
More Related Videos
07:07A Novel Scalp Acupuncture-based Method to Target the Hand Motor Hotspot for Non-invasive Brain Stimulation
Published on: December 19, 2025
08:27Three-Dimensional Finger Motion Tracking during Needling: A Solution for the Kinematic Analysis of Acupuncture Manipulation
Published on: October 28, 2021