Simple analog circuitry for measuring time to peaks.

F L Abel

    The American Journal of Physiology
    |May 1, 1979
    PubMed
    Summary

    This study presents two analog circuits for measuring waveform peak times. The circuits utilize triggered and reset analog integrators for accurate time-to-peak measurements.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Beat-to-beat evaluation of cardiac function in low-dose endotoxemia using a conscious sheep model.

    Shock (Augusta, Ga.)·2001
    Same author

    Pmax, end systolic elastance, and Starling's law of the heart.

    Shock (Augusta, Ga.)·2001
    Same author

    Effects of hyperbaric oxygen on ventricular performance, pulmonary blood volume, and systemic and pulmonary vascular resistance.

    Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc·2000
    Same author

    Cardiac contractility and structure are not significantly compromised even during the late, hypodynamic stage of sepsis. Mian Zhou, Ping Wang, and Irshad H. Chaudry. Shock 9(5):352-358, 1998.

    Shock (Augusta, Ga.)·1999
    Same author

    Left ventricular potential energy is represented in the ejecting left ventricular pressure curve.

    Shock (Augusta, Ga.)·1998
    Same author

    Problems with use of the end systolic pressure-volume slope as an indicator of left ventricular contractility: an alternate method.

    Shock (Augusta, Ga.)·1998

    Area of Science:

    • Electronics
    • Signal Processing
    • Instrumentation

    Background:

    • Accurate measurement of waveform characteristics is crucial in various scientific and engineering fields.
    • Existing methods for determining time-to-peak may be complex or require specialized equipment.

    Purpose of the Study:

    • To introduce two novel, simple analog circuits for the precise measurement of time to the peak of a waveform.
    • To provide an accessible and cost-effective solution for time-to-peak analysis.

    Main Methods:

    • The proposed circuits employ analog integration principles.
    • A triggered and reset analog integrator is utilized to capture and measure the time duration until the waveform reaches its peak amplitude.

    Main Results:

    • The developed analog circuits successfully measure the time to the peak of a waveform.
    • The simplicity of the design allows for straightforward implementation and operation.

    Conclusions:

    • The presented analog circuits offer a practical and efficient method for determining time-to-peak measurements.
    • These circuits can be valuable tools in applications requiring waveform analysis.