Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

662
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over...
662
Design Example: Measuring Distance Between Two Points with Obstructions01:10

Design Example: Measuring Distance Between Two Points with Obstructions

502
When measuring distances in areas with physical obstructions, such as a lake in a field, surveyors must employ techniques to calculate accurate lengths without direct line measurements. One effective method is the offset technique, which allows for precise distance estimation over inaccessible stretches.In this scenario, a surveyor must measure a side of an area that crosses a lake. Since the measuring tape cannot span the lake, the surveyor begins by establishing a baseline that aligns with...
502
Distance Measurements by Taping01:18

Distance Measurements by Taping

612
Tapes are essential in surveying for accurate, durable, and short-distance measurements. Made from lightweight, nylon-coated steel, they offer flexibility and strength for rugged outdoor use. The nylon coating protects against rust and wear, extending the tape's life. Standard lengths, around 30 meters, are marked in meters and millimeters for precision.Surveyors select tapes based on site conditions and accuracy needs. Lightweight, nylon-coated tapes are commonly used for ease of handling and...
612
Measurement: Derived Units03:02

Measurement: Derived Units

57.5K
The International System of Units or SI system, by international agreement, has fixed measurement units for seven fundamental properties: length, mass, time, temperature, electric current, amount of substance, and luminosity. These are called the SI base units.
57.5K
Measurement: Standard Units03:38

Measurement: Standard Units

85.8K
Every measurement provides three kinds of information: the size or magnitude of the measurement (a number), a standard of comparison for the measurement (a unit), and an indication of the uncertainty of the measurement. While the number and unit are explicitly represented when a quantity is written, the uncertainty is an aspect of the errors in the measurement results.
85.8K
SI Units: 2019 Redefinition01:13

SI Units: 2019 Redefinition

4.0K
Measurement is an indispensable part of analytical chemistry. The result of measurement helps quantify a substance's physical property and compare it with the physical property of another substance. Each measurement comprises two components - a number indicating the magnitude and a unit of measurement as a standard for comparison. Further, the same quantity can be measured using different units of measurement, which leads to differences in magnitude.
A standard set of units has been defined...
4.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Heart Lesions Produced by the Deep X-Ray: An Experimental and Clinical Study.

Transactions of the American Climatological and Clinical Association. American Climatological and Clinical Association·2011
Same author

Sleep-dependent activity of T cells and regulatory T cells.

Clinical and experimental immunology·2008
Same author

Fluorescence microlymphography: diagnostic potential in lymphedema and basis for the measurement of lymphatic pressure and flow velocity.

Lymphology·2007
Same author

[Aneurysms from the viewpoint of medical history].

VASA. Zeitschrift fur Gefasskrankheiten·2003
Same author

Microlymphatic aneurysms in patients with lipedema.

Lymphology·2002
Same author

The "galloping" history of intermittent claudication.

VASA. Zeitschrift fur Gefasskrankheiten·2001
Same journal

Lower LDL-c/ApoB ratio is associated with adverse cardiovascular outcomes and advanced peripheral artery disease.

VASA. Zeitschrift fur Gefasskrankheiten·2026
Same journal

A new era in carotid prevention - critical appraisal of the CREST-2 results.

VASA. Zeitschrift fur Gefasskrankheiten·2026
Same journal

Management of venous thromboembolism in France - a nationwide clinical practice survey among vascular medicine specialists.

VASA. Zeitschrift fur Gefasskrankheiten·2026
Same journal

Endovascular salvage of distal infrainguinal bypass anastomotic stenosis following thrombectomy using a heparin-bonded covered stent.

VASA. Zeitschrift fur Gefasskrankheiten·2026
Same journal

Optimal ablation length for effective treatment of great saphenous vein insufficiency.

VASA. Zeitschrift fur Gefasskrankheiten·2026
Same journal

Long-term outcomes of covered versus bare metal stents in the reconstruction of the aortic bifurcation.

VASA. Zeitschrift fur Gefasskrankheiten·2026
See all related articles

Related Experiment Video

Updated: Mar 24, 2026

Evaluating Usability Aspects of a Mixed Reality Solution for Immersive Analytics in Industry 4.0 Scenarios
06:02

Evaluating Usability Aspects of a Mixed Reality Solution for Immersive Analytics in Industry 4.0 Scenarios

Published on: October 6, 2020

2.7K

[Editorial: Measuring methods from the futurological viewpoint]

A Bollinger

    VASA. Zeitschrift Fur Gefasskrankheiten
    |January 1, 1973
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
    06:52

    An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field

    Published on: May 26, 2020

    8.8K
    High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques
    11:34

    High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques

    Published on: December 3, 2013

    16.1K

    Related Experiment Videos

    Last Updated: Mar 24, 2026

    Evaluating Usability Aspects of a Mixed Reality Solution for Immersive Analytics in Industry 4.0 Scenarios
    06:02

    Evaluating Usability Aspects of a Mixed Reality Solution for Immersive Analytics in Industry 4.0 Scenarios

    Published on: October 6, 2020

    2.7K
    An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
    06:52

    An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field

    Published on: May 26, 2020

    8.8K
    High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques
    11:34

    High-resolution, High-speed, Three-dimensional Video Imaging with Digital Fringe Projection Techniques

    Published on: December 3, 2013

    16.1K