A new electrical equipment for handgrip testing.

S Malinen, K Virtanen, M H Frick

    Annals of Clinical Research
    |June 1, 1979
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    The impact of alcohol on fall-related maxillofacial fractures: a retrospective study.

    International journal of oral and maxillofacial surgery·2026
    Same author

    Decreased thioredoxin-1 and increased HSP90 expression in skeletal muscle in subjects with type 2 diabetes or impaired glucose tolerance.

    BioMed research international·2014
    Same author

    Assessment of MAO-B occupancy in the brain with PET and [11C]-L-deprenyl-D2: a dose-finding study with a novel MAO-B inhibitor, EVT 301.

    Clinical pharmacology and therapeutics·2009
    Same author

    Amino-acid-based peritoneal dialysis solution improves amino-acid transport into skeletal muscle.

    Kidney international. Supplement·2008
    Same author

    Remnant-like lipoprotein particle cholesterol concentration and progression of coronary and vein-graft atherosclerosis in response to gemfibrozil treatment.

    Atherosclerosis·2001
    Same author

    Fibrinolytic proteins and progression of coronary artery disease in relation to gemfibrozil therapy.

    Thrombosis and haemostasis·2000
    Same journal

    Dietary lipids and ischaemic heart disease--progress in 20 years.

    Annals of clinical research·1988
    Same journal

    Exercise prescription in medical practice.

    Annals of clinical research·1988
    Same journal

    More exercise for the hyperlipidaemic patients?

    Annals of clinical research·1988
    Same journal

    More exercise for the hypertensives?

    Annals of clinical research·1988
    Same journal

    More exercise for the obese?

    Annals of clinical research·1988
    Same journal

    Physical activity and effects of muscle training in the elderly.

    Annals of clinical research·1988
    See all related articles

    This study introduces a new electrical device for isometric handgrip testing, improving accuracy over older designs. The improved handgrip testing equipment helps patients maintain consistent force for reliable medical data.

    Area of Science:

    • Biomedical Engineering
    • Medical Device Design
    • Clinical Measurement

    Background:

    • Existing isometric handgrip testing devices have design flaws leading to inaccurate measurements.
    • Accurate handgrip force measurement is crucial for various clinical assessments and research.

    Purpose of the Study:

    • To develop and evaluate a novel electrical device for isometric handgrip testing.
    • To overcome the limitations of previous handgrip testing equipment and enhance data reliability.

    Main Methods:

    • A new U-shaped handgrip transducer and electronic system was designed and constructed.
    • The device measures maximum handgrip force as peak voltage and uses comparators for feedback.
    • A slave monitor with visual cues assists patients in maintaining target force levels.

    Related Experiment Videos

    Main Results:

    • The new device accurately captures peak handgrip force as a stored analog voltage.
    • Patient feedback via the slave monitor effectively guided force maintenance at selected percentages.
    • The equipment demonstrated reliable performance in a longitudinal study for hypertension drug treatment.

    Conclusions:

    • The newly developed electrical device significantly improves the accuracy and reliability of isometric handgrip testing.
    • This innovation offers a more precise tool for clinical research and patient monitoring, particularly in studies like hypertension treatment.
    • The design addresses critical constructional deficiencies found in prior isometric handgrip testing apparatus.