[New technical possibilities for simultaneous cystometry].

J Wehnert, R Werthschützky

    Zeitschrift Fur Urologie Und Nephrologie
    |September 1, 1979
    PubMed
    Summary

    Integrated semiconductor pressure sensors optimize urodynamic examinations by directly measuring bladder pressure, reducing errors from conventional methods. This advancement improves accuracy in diagnosing urinary tract conditions.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Miniaturized force/torque sensor for in vivo measurements of tissue characteristics.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2017
    Same author

    Characteristic of a force sensing guide wire for minimally invasive cardiac surgery.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2017
    Same author

    [Methods of resolution for haptic assistance during catheterization].

    Biomedizinische Technik. Biomedical engineering·2005
    Same author

    [Telemetric system for measuring the pressure of the tongue on the palate].

    Biomedizinische Technik. Biomedical engineering·2003
    Same author

    [Piezoresistive sensors for medical applications exemplified by a probe for measure pressure in the rectum].

    Biomedizinische Technik. Biomedical engineering·2002
    Same author

    Automated CT image evaluation of the lung: a morphology-based concept.

    IEEE transactions on medical imaging·2001

    Area of Science:

    • Urology
    • Biomedical Engineering
    • Medical Instrumentation

    Context:

    • Conventional urodynamic examinations using fluid or gas-filled catheters are susceptible to errors.
    • These errors include hydrostatic influences, catheter movement, and blockages from hematuria or mucus.
    • Accurate pressure manometry is crucial for diagnosing bladder and urethral conditions.

    Purpose:

    • To introduce an optimized manometry method for bladder and urethra examination.
    • To eliminate measurement errors associated with traditional urodynamic techniques.
    • To present the IBW 74 tip manometer for enhanced pressure signal acquisition.

    Summary:

    • Integrated semiconductor pressure sensors, directly placed within the bladder lumen, enhance urodynamic manometry.
    • This novel approach minimizes errors caused by fluid dynamics, hydrostatic pressure variations, and catheter obstructions.
    • The IBW 74 tip manometer, with its radiopaque properties, is suitable for measuring pressure in the upper urinary tract, including the renal pelvis.

    Impact:

    • Improved diagnostic accuracy in urodynamics and urological assessments.
    • Reduced patient discomfort and procedural complications associated with conventional methods.
    • Potential for broader application in monitoring upper urinary tract pressures.