Related Experiment Video
Updated: Oct 5, 2026

Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Blood flow in the contralateral hand during vibration and hand grip contractions of lumberjacks
Abstract:
Pulse wave changes were examined among 63 professional lumberjacks. The tests were carried out in connection with an annual health examination. A photoelectric plethysmographic method was used to measure pulse wave changes during contralateral muscle work and vibration exposure from a dynamic shaker with a strain-gauge dynamometer. The relative changes in pulse wave amplitude were counted, and the changes were classified as dilatations, constrictions, or constant pulse wave amplitude. Contralateral muscle work caused vasodilatation, but vibration exposure could cause vasoconstrictions in the right hand. Most of the vasospasms were recorded at 60 and 100 Hz. The strongest vasospasms were seen at 200 Hz. The occurrence of vasospasms in the contralateral hand correlated with the severity of white finger symptoms rated according to an index for traumatic vasospastic disease.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi radialis,...
Arteries of the Upper Limbs
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection

