Related Experiment Video
Updated: Aug 10, 2026

Watershed Planning within a Quantitative Scenario Analysis Framework
Published on: July 24, 2016
Thermal pollution consequences of the implementation of the president's energy message on increased coal utilization
Abstract:
The thermal consequences of coal utilization are most meaningfully assessed in comparison with the form of power generation replaced by coal which is most likely nuclear. The different effects are influenced by siting decisions and the intrinsic thermal efficiencies of the two fuel systems. Nuclear power plants discharge 50% more waste Rheat to the atmosphere through cooling towers or to a water body than coal-fired plants. Coal-fired plants require about 2/3 as much water as nuclear power plants. Nearly every property of water is affected nonlinearly by temperature, and biological effects may amplify these changes because protein denaturation takes place more rapidly above 30 degrees C and these high temperatures affect bactericidal and viricidal activity of chlorine compounds. Usually algal populations change from a dominance of diatoms and green algae to dominance by blue-green algae. All organisms experience elevated metabolic rates at higher temperatures which may affect total energy needs, foraging ability, reproduction, migration and susceptibility to disease. Intake structures inevitably draw many organisms into the cooling system of a power plant, but the number and kind are influenced by its location, configuration, and mode of operation. Use of water recirculation systems reduces water use and with it, the number of organisms entrained. Mechanical damage in the cooling system to small organisms is generally low, but fish and their larvae and eggs may be seriously damaged. Discharge effects may also be severe but are generally local. The near field, where there are strong shear velocities and rapid temperature changes are particularly stressful to fish, and stringent limitations on the timing and strength of discharges may be required to reduce these stresses to nondamaging levels. Off-stream cooling systems may increase cloudiness, ground fog, precipitation, temperature and local winds, but these effects generally extend no further than 1000 m even in winter. There is considerable potential for using condenser cooling water for agricultural and aquacultural purposes such as irrigation, frost protection, undersoil heating, greenhouse heating and climate control. However, over the next few decades little of this waste heat is likely to be used creatively. The thermal consequences of implementing NEP are locally serious but do not pose regional problems. Creative use of the waste heat for aquaculture, agriculture, cogeneration, and power for energy intensive industries can be a powerful means of mitigating undesirable effects.
Related Concept Videos
Bioremediation
Global Climate Change
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Acid Mine Drainage
Biofuels

