Related Experiment Video
Updated: Jun 16, 2026

Microperfusion Technique to Investigate Regulation of Microvessel Permeability in Rat Mesentery
Published on: September 12, 2015
Correlation of variations in intraluminal pressure and potential differences in the perfused colen
Abstract:
To investigate the nature of variations in the large intestine potential differences, a continuous perfusion of isotonic saline was carried out in the colon of 14 rats. Intraluminal pressure and potential differences between the lumen and the peritoneal cavity were continuously and simultaneously recorded, while impedance of the system and respiration were also constantly monitored. To obtain a quantitative evaluation of the data, Fast Fouier Transform was performed on the signals and their derivatives which were auto- and cross-correlated. While there was no obvious relation between pressure and potential in the unperfused colon, there was clear visual qualirative evidence that, during steady state conditions of perfusion, an increase in intraluminal pressure was accompanied by a decrease in potential differences, while impedance of the recording system remained unchanged. Computer analysis disclosed four narrow ranges of stable frequencies for both pressure and potential. They were centred around 0-3, 1-75, 10-7, and 75 cycles per minute, the latter being synchronous with respiration. It is concluded that the variations of potential differences recorded during perfusion, a well-know phenomenon, are not electrical artefacts: the fast rhythm is probably induced by respiration, which increases intracolonic pressure and that, in turn, reduces the absolute value of potential differences, which remain negative mucosa versus serosa. The slower rhythms are synchronous for pressure and potential. Mechanisms responsible for the decrease in potential related to the increase in pressure remain unknown.
Related Concept Videos
Capillary Exchange
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in pressure...
Intestinal Obstruction II: Pathophysiology

