[New high-capacity sampling device for controlling air dust content].

A Kovachev

    Problemi Na Khigienata
    |January 1, 1977
    PubMed
    Summary

    A new high-capacity dust sampling device with an electric aspirator was developed for accurate air pollution monitoring in workplaces and general atmosphere. This innovative apparatus precisely measures and regulates air capacity for effective dust control and analysis.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Effect of Linearization in a WNT Signaling Model.

    Computational and mathematical methods in medicine·2019
    Same author

    [Beta therapy of vulvar leukoplakia].

    Meditsinskaia radiologiia·1990
    Same author

    [Inertial separation of dust particles in a direct-flow field].

    Problemi na khigienata·1988
    Same author

    [Method and apparatus setup for preparing test dusts with a specified granulometric composition by air separation].

    Problemi na khigienata·1987
    Same author

    [Basic work environment factors at the Kremikovtsi Coke Chemical Plant].

    Problemi na khigienata·1981
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies

    Area of Science:

    • Environmental Engineering
    • Occupational Health and Safety

    Context:

    • Industrial hygiene requires precise monitoring of airborne dust.
    • Existing methods may lack the capacity or accuracy for comprehensive dust analysis.

    Purpose:

    • To introduce a novel high-capacity dust sampling device for accurate air pollution assessment.
    • To provide a reliable tool for weight analyses of dust in various environments.

    Summary:

    • The device features a unique sample-taking head that measures and regulates air capacity between 50-200 dm3/min.
    • It utilizes FPP-15 filters (80 mm diameter) for efficient dust collection.
    • Sampling adheres to national dust control standards.

    Impact:

    • Enhances the accuracy and efficiency of dust pollution control measures.
    • Supports compliance with occupational health and safety regulations.
    • Facilitates reliable environmental monitoring for improved air quality.