The use of cross-correlation function for the alignment of ECG waveforms and rejection of extrasystoles
Abstract:
The cross-correlation function for alignment of ECG waveforms and rejection of artifacts was studied. ECG waveforms were recorded and digitized (10-bit resolution) at 1.28 KHz and were processed with a CDC 6600 computer. The cross-correlation function was calculated using the cross spectrum and the fast Fourier transform algorithm. The maximum value of the cross-correlation function and the time location of that value were searched for (a) the similarity between the waveforms (for elimination of extrasystoles), and (b) measuring the relative time delay (for the waveform's alignment in the averaging process) between the ECG waveforms. Prior to the correlation procedure each of the ECG waveforms was filtered through a nonrecursive digital bandpass filter. Experiments with various filters indicated that when low-frequency cutoff at 30 Hz and high-frequency cutoff at 250 Hz were used the maximum value of the cross-correlation function was higher than 0.9 for most of our recorded waveforms and more accurate results were obtained.
More Related Videos
10:23Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
Published on: June 23, 2023
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...