Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Percutaneous balloon pulmonary valvuloplasty
Insights
Percutaneous balloon pulmonary valvuloplasty effectively treated pulmonary stenosis in pediatric patients. This minimally invasive procedure significantly reduced pressure gradients across the pulmonary valve without impacting cardiac output.
Area of Science:
- Cardiology
- Interventional Cardiology
- Pediatric Cardiology
Background:
- Pulmonary stenosis (PS) is a significant congenital heart defect.
- Valvular PS requires effective treatment to prevent right ventricular strain.
- Percutaneous balloon pulmonary valvuloplasty (BPV) is a less invasive option.
Purpose of the Study:
- To evaluate the efficacy and safety of BPV in pediatric patients with isolated valvular PS.
- To assess the impact of BPV on pulmonary valve gradients and right ventricular pressures.
Main Methods:
- 18 consecutive patients with valvular PS underwent BPV.
- Balloon inflations were performed at 80, 100, and 120 psi.
- Hemodynamic parameters, including peak systolic pulmonary valve gradient (delta P), were measured pre- and post-procedure.
Main Results:
- BPV significantly reduced the mean delta P from 81 +/- 31 mm Hg to 23 +/- 11 mm Hg (p < 0.01).
- Right ventricular peak systolic pressure decreased from 106 +/- 31 to 50 +/- 12 mm Hg (p < 0.01).
- No pulmonary regurgitation was observed post-BPV.
Conclusions:
- BPV is a safe and effective treatment for valvular PS in children and young adults.
- The procedure leads to significant hemodynamic improvement.
- BPV may serve as an alternative to surgical intervention for PS.
Abstract:
Percutaneous balloon pulmonary valvuloplasty (BPV) was performed in 18 consecutive patients with valvular pulmonary stenosis (PS) with no associated cardiac defects. The patients were 11 months to 19 years of age. The balloon was positioned across the pulmonary valve and inflated to pressures of 80, 100, and 120 pounds/square inch (psi). Each inflation lasted approximately 10 seconds. Peak systolic pulmonary valve gradient (delta P) and cardiac output were measured before and 15 minutes after BPV. There was no change in cardiac output, but all patients had an improved delta P. The prevalvuloplasty delta P was 81 +/- 31 mm Hg, decreasing to 23 +/- 11 mm Hg after BPV (p less than 0.01). The right ventricular peak systolic pressure decreased from 106 +/- 31 to 50 +/- 12 mm Hg (p less than 0.01). No pulmonary regurgitation was noted after BPV. The balloons were 12 or 15 mm in diameter, chosen according to the diameter of the pulmonary valve anulus. Pressures of 100 to 120 psi were required to achieve full inflation of the balloons. BPV also was performed in a patient with tetralogy of Fallot. Subsequent total repair provided an opportunity to observe the mechanism of the dilatation. Evidence of a small tear alongside the anterior valve raphe was noted. BPV induced a significant decrease in delta P and may offer an alternative method for treating PS.
More Related Videos
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mitral Stenosis III: Medical Management
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care