Accuracy of precordial palpation for detecting increased left ventricular volume
Abstract:
Objective data on the reliability of precordial palpation in detecting left ventricular enlargement are scarce. Therefore, we evaluated 41 patients by physical examination and two-dimensional echocardiography to determine the relation between the location of the apex and left ventricular end-diastolic volume. An apical impulse lateral to the mid-clavicular line or greater than 10 cm from the mid-sternal line was sensitive but not specific as an indicator of left ventricular enlargement. In patients without left ventricular hypertrophy, an apical diameter greater than 3 cm in the left lateral decubitus was sensitive (92%) and specific (91%) for an enlarged left ventricle. The positive and negative predictive values were 86% and 95% respectively. Therefore, the location of the apical impulse in relation to the mid-clavicular line or the mid-sternal line is not a reliable indicator of increased left ventricular end-diastolic volume. However, an apical impulse greater than 3 cm may be an accurate indicator of left ventricular enlargement.
More Related Videos
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of the Abdomen III: Palpation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection