Related Experiment Video
Updated: Aug 10, 2026

Intraoperative Gastroscopy for Tumor Localization in Laparoscopic Surgery for Gastric Adenocarcinoma
Published on: August 9, 2016
Insertion of the laparoscopic Trocar without the use of carbon dioxide gas
Abstract:
Nine-hundred-and-fourteen patients have undergone the single puncture Falope Ring laparoscopic tubal ligations in a community hospital without prior insufflation of carbon dioxide gas. Anesthesia time averaged 10.5 minutes, surgical procedure time averaged 8.1 minutes. The patients left the hospital in satisfactory condition in the afternoon of the procedure. The only complication was a failed ligation (0.1%). Two-week follow-up showed no untoward complications. Omission of carbon dioxide insufflation before Trocar insertion lowers complications such as nausea, emesis, and post-operative pain. Also, anesthesia and surgical times are reduced. None of the patients required intubation during anesthesia.
More Related Videos
09:04Low-Cost Single-Port (LoCoSP) Device for a Transcervical Approach in Minimally Invasive Transhiatal Esophagectomy
Published on: September 11, 2021
08:26Clinical Application of Single-Surgeon, Three-Port, Laparoscopic Resection for Colorectal Cancer with Natural Orifice Specimen Extraction
Published on: March 24, 2023