Related Experiment Videos
Lung scan interpretation: effect of different observers and different criteria
Radiology
|December 1, 1983
Summary
Interobserver variation in interpreting lung scintigrams is high. However, no single interpretation scheme proved superior, though Biello and modified criteria reduced indeterminate classifications without impacting accuracy.
Area of Science:
- Nuclear Medicine
- Radiology
- Medical Imaging
Background:
- Physicians interpret lung scintigrams using various criteria (McNeil, Biello et al., or integrated approaches).
- Interobserver variability and comparative effectiveness of these interpretation schemes are not well-established.
Purpose of the Study:
- To assess interobserver variation in lung scintigram interpretation.
- To compare the diagnostic performance of different interpretation criteria (McNeil, Biello, and modified criteria).
Main Methods:
- Two experienced nuclear medicine physicians independently reviewed 98 lung scintigrams with angiographic correlation.
- Objective descriptions of perfusion, ventilation, and radiographic abnormalities were recorded.
- Scans were categorized using McNeil and Biello criteria, and a modified criteria set.
Main Results:
- Significant interobserver variation was noted in describing scan abnormalities.
- No statistically significant differences were found between receiver operating characteristic (ROC) curves for individual readers or criteria sets.
- Biello and modified criteria reduced indeterminate classifications without compromising accuracy.
- A significant difference in overall accuracy was observed between the two study years.
Conclusions:
- Current lung scintigram interpretation criteria exhibit substantial interobserver variation.
- No single criterion set demonstrated clear superiority in diagnostic accuracy.
- Modified and Biello criteria may offer advantages in reducing indeterminate interpretations.
- Year-to-year variations in accuracy highlight potential issues in retrospective studies.