Related Experiment Video
Updated: Aug 9, 2026

Recapitulation of an Ion Channel IV Curve Using Frequency Components
Published on: February 8, 2011
Temperature dependence of ion permeation at the endplate channel
Abstract:
The dependence of acetylcholine receptor mean single-channel conductance on temperature was studied at garter snake twitch-muscle endplates using fluctuation analysis. In normal saline under conditions where most of the endplate current was carried by Na+, the channel conductance increased continuously from near 0 degrees C to approximately 23 degrees C with a Q10 of 1.97 +/- 0.14 (mean +/- SD). When 50% of the bath Na+ was replaced by either Li+, Rb+, or Cs+, the Q10 did not change significantly; however, at any temperature the channel conductance was greatest in Cs-saline and decreased with the ion sequence Cs greater than Rb greater than Na greater than Li. The results were fit by an Eyring-type model consisting of one free-energy well on the extracellular side of a single energy barrier. Ion selectivity appeared to result from ion-specific differences in the well and not in the barrier of this model. With a constant barrier enthalpy for different ions, well free-energy depth was greatest for Cs+ and graded identical to the permeability sequence. The correlation between increased well depth (i.e., ion binding) and increased channel conductance can be accounted for by the Boltzmann distribution of thermal energy.
More Related Videos
11:42Reconstitution of a Transmembrane Protein, the Voltage-gated Ion Channel, KvAP, into Giant Unilamellar Vesicles for Microscopy and Patch Clamp Studies
Published on: January 22, 2015
05:42Measurement of Ion Concentration in the Unstirred Boundary Layer with Open Patch-Clamp Pipette: Implications in Control of Ion Channels by Fluid Flow
Published on: January 7, 2019
Related Concept Videos
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow specific...
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential.
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Mechanically-gated Ion Channels
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Mechanically-gated Ion Channels