Rapid access airway: surgical device and technique.

R E Lassa, M B Habal, N Ross

    International Surgery
    |March 1, 1978
    PubMed
    Summary

    A new, affordable device offers quick, temporary subglottic airway access for oxygenation and anesthesia. It is safe and effective in emergencies, difficult inductions, and pediatric cases with airway challenges.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    A one-generation reproductive toxicity study of the mycotoxin ochratoxin A in Fischer rats.

    Food and chemical toxicology : an international journal published for the British Industrial Biological Research Association·2021
    Same author

    Recent Innovations & Daily Problems.

    Hernia : the journal of hernias and abdominal wall surgery·2015
    Same author

    Cosmetic advantages of augmenting the hypoplastic breast via the transaxillary route.

    Aesthetic plastic surgery·2013
    Same author

    The invisible frown plasty.

    Aesthetic plastic surgery·2013
    Same author

    Interface pressures in below elbow casts.

    Clinical biomechanics (Bristol, Avon)·2013
    Same author

    Multilevel-grating array generators: fabrication error analysis and experiments.

    Applied optics·2010

    Area of Science:

    • Anesthesiology
    • Emergency Medicine
    • Pediatric Airway Management

    Background:

    • Establishing a patent airway is critical in emergency medicine and anesthesia.
    • Difficult intubation, particularly in pediatric patients with supraglottic disorders, poses significant challenges.
    • Temporary airway access is often required before definitive airway management.

    Purpose of the Study:

    • To present a novel, simple, and inexpensive device for immediate temporary subglottic airway access.
    • To evaluate the utility of this device in emergency situations, difficult anesthesia inductions, and pediatric cases.
    • To assess the safety and efficacy of the device for oxygenation and anesthesia induction.

    Main Methods:

    • A readily assembled device was developed to provide access to the subglottic airway.
    • The device was utilized for oxygenation and anesthesia induction in various clinical scenarios.
    • Clinical outcomes, including successful airway access and patient safety, were monitored.

    Main Results:

    • The device provides immediate temporary access to the subglottic airway.
    • It proved effective in emergency clinical situations and during difficult anesthesia inductions.
    • The device was successfully used in pediatric patients with supraglottic disorders, facilitating anesthesia prior to tracheostomy.

    Conclusions:

    • The presented device offers a simple, inexpensive, and readily available solution for temporary subglottic airway access.
    • Its application is beneficial in emergency settings, challenging anesthetic inductions, and pediatric cases with airway difficulties.
    • No morbidity or mortality was associated with the use of this device, highlighting its safety profile.