Related Experiment Videos
Electrical characteristics of the isolated dog ciliary body
Current Eye Research
|March 1, 1984
Abstract:
Transepithelial potential difference and short-circuit current of the dog ciliary body were measured in vitro in an Ussing-type chamber using HEPES-buffered solution containing bicarbonate. Their values were -1.35 +/- 0.08 mV (mean +/- S.E.M., n = 52) and -23.6 +/- 1.7 microA/cm2, respectively. At 10(-4) M, ouabain reduced the short-circuit current upon to either side of the chamber. On the other hand, at 10(-5) M of furosemide to the aqueous side, the short-circuit current was reduced. However even at 10(-3) M, this drug had no effect when applied to the stromal side. Behavior of the dog ciliary body towards these two inhibitors was compared with that of the toad and rabbit tissues.