Transmission electron microscopy and serial sections for light microscopy from the same block in routine renal
American Journal of Clinical Pathology
|October 1, 1983
Summary
This study introduces a new technique for renal pathology, enabling immediate transmission electron microscopy (TEM) sections from the same block used for high-resolution light microscopy (HRLM). This simplifies the process, saving time and preserving valuable tissue samples.
Area of Science:
- Nephrology
- Pathology
- Microscopy
Background:
- Current renal pathology practices involve separate samples for light microscopy (LM) and transmission electron microscopy (TEM).
- Existing methods for obtaining both high-resolution light microscopy (HRLM) and TEM from the same block are not practical for routine renal biopsies.
- Re-embedding or mesa techniques for TEM from HRLM blocks are time-consuming and can waste tissue.
Purpose of the Study:
- To present a novel technique for obtaining immediate TEM sections from the same block used for HRLM in renal pathology.
- To streamline the process of correlative LM and TEM analysis of renal biopsies.
- To avoid fragmentation and waste of valuable tissue samples during serial sectioning.
Main Methods:
- A new technique allows for the production of immediate TEM sections from different areas of the same HRLM block.
- Serial sections for HRLM are mounted on slides with multiple wells.
- TEM sections are obtained within two hours after HRLM screening.
Main Results:
- The described method produces large HRLM and TEM sections within 24 hours.
- This technique avoids the need for separate samples for LM and TEM studies.
- The method is simple, does not fragment the block, and preserves tissue integrity.
Conclusions:
- The presented technique offers a significant improvement for routine renal biopsy analysis.
- Immediate correlative HRLM and TEM analysis is now feasible and efficient.
- This method simplifies workflow and enhances diagnostic capabilities in renal pathology.