Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

2.9K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.9K
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

2.5K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
2.5K
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

1.4K
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.4K
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

2.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.3K
Pipe Flowrate Measurement01:28

Pipe Flowrate Measurement

1.1K
In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
1.1K
Sites for measruring blood pressure01:21

Sites for measruring blood pressure

3.2K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
3.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The compensatory anti-inflammatory cytokine interleukin 10 response in pediatric sepsis-induced multiple organ failure.

Chest·1998
Same author

Control of photosystem formation in Rhodobacter sphaeroides.

Journal of bacteriology·1998
Same author

Cascade regulation of dimethyl sulfoxide reductase (dor) gene expression in the facultative phototroph Rhodobacter sphaeroides 2.4.1T.

Journal of bacteriology·1998
Same author

FEESST: a new bedside endoscopic test of the motor and sensory components of swallowing.

The Annals of otology, rhinology, and laryngology·1998
Same author

Left ventricular structure and function in children infected with human immunodeficiency virus: the prospective P2C2 HIV Multicenter Study. Pediatric Pulmonary and Cardiac Complications of Vertically Transmitted HIV Infection (P2C2 HIV) Study Group.

Circulation·1998
Same author

Posttraumatic stress disorder and family functioning in adolescent cancer.

Journal of traumatic stress·1998

Related Experiment Video

Updated: Jan 4, 2026

A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine
08:27

A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine

Published on: December 6, 2024

614

Method of measuring blood loss.

S Kaplan

    Anaesthesia
    |February 1, 1978
    PubMed
    Summary

    A new osmolality dilution technique offers a rapid and easy method for calculating blood loss in pediatric surgery. This laboratory-validated approach shows promise for accurate intraoperative blood loss measurement.

    Area of Science:

    • Biomedical Engineering
    • Clinical Chemistry
    • Pediatric Surgery

    Background:

    • Accurate intraoperative blood loss estimation is critical in pediatric surgery.
    • Existing methods for measuring blood loss can be time-consuming or inaccurate.
    • There is a need for a rapid, reliable method to quantify blood loss during pediatric procedures.

    Purpose of the Study:

    • To describe and validate a novel osmolality dilution technique for calculating blood loss.
    • To assess the feasibility of using this technique for intraoperative blood loss measurement in pediatric patients.

    Main Methods:

    • The osmolality dilution technique was employed to measure known volumes of blood components (whole blood, packed red blood cells, plasma) in a laboratory setting.
    • Statistical analysis was performed on the collected laboratory data.

    More Related Videos

    Tail Vein Transection Bleeding Model in Fully Anesthetized Hemophilia A Mice
    08:13

    Tail Vein Transection Bleeding Model in Fully Anesthetized Hemophilia A Mice

    Published on: September 30, 2021

    7.2K
    Uncontrolled Hemorrhagic Shock Modeled via Liver Laceration in Mice with Real Time Hemodynamic Monitoring
    06:11

    Uncontrolled Hemorrhagic Shock Modeled via Liver Laceration in Mice with Real Time Hemodynamic Monitoring

    Published on: May 21, 2017

    9.0K

    Related Experiment Videos

    Last Updated: Jan 4, 2026

    A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine
    08:27

    A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine

    Published on: December 6, 2024

    614
    Tail Vein Transection Bleeding Model in Fully Anesthetized Hemophilia A Mice
    08:13

    Tail Vein Transection Bleeding Model in Fully Anesthetized Hemophilia A Mice

    Published on: September 30, 2021

    7.2K
    Uncontrolled Hemorrhagic Shock Modeled via Liver Laceration in Mice with Real Time Hemodynamic Monitoring
    06:11

    Uncontrolled Hemorrhagic Shock Modeled via Liver Laceration in Mice with Real Time Hemodynamic Monitoring

    Published on: May 21, 2017

    9.0K

    Main Results:

    • The osmolality dilution technique demonstrated accuracy in measuring known volumes of various blood components.
    • Statistical analysis indicated a high degree of reliability for the method.

    Conclusions:

    • The described osmolality dilution technique is a potentially valuable tool for rapid and accurate blood loss calculation.
    • This method shows significant promise for practical application in operating theaters during pediatric surgery.