Related Experiment Videos
[Nova-T and Copper-T in a 5 years' comparison]
Geburtshilfe Und Frauenheilkunde
|March 1, 1984
Summary
The Nova-T intra-uterine contraceptive device demonstrated superior efficacy compared to the copper-T-200, with a lower pregnancy rate and better retention. Fertility returned normally after use, highlighting Nova-T as an excellent contraceptive option.
Area of Science:
- Reproductive Health
- Medical Devices
- Contraception
Background:
- Intra-uterine contraceptive devices (IUCDs) are a common form of reversible contraception.
- Comparative studies are essential to evaluate the efficacy and safety of different IUCD models.
- The Nova-T and Copper-T-200 are widely used IUCDs with distinct designs.
Purpose of the Study:
- To compare the five-year efficacy and safety of the Nova-T and Copper-T-200 intra-uterine contraceptive devices.
- To assess pregnancy rates, expulsion rates, and device retention in relation to age and parity.
- To evaluate the ease of insertion and removal, and the return of fertility after device use.
Main Methods:
- A five-year multi-centre randomized comparative study.
- Inclusion of 1865 insertions of Nova-T and Copper-T-200 devices.
- Data collection on Pearl Index, pregnancy rates, expulsion, insertion/removal complications, and return of fertility.
Main Results:
- The cumulative five-year Pearl Index was 0.8 for Nova-T and 2.0 for Copper-T-200.
- Nova-T showed lower pregnancy rates across all subgroups (country, age, parity).
- Nova-T exhibited better retention, with expulsion rates less influenced by age and parity compared to Copper-T-200. Insertion and removal were uncomplicated, and fertility returned promptly.
Conclusions:
- Nova-T is an excellent intra-uterine contraceptive device with superior efficacy and retention compared to Copper-T-200.
- The device's design facilitates easy insertion and removal, contributing to its favorable safety profile.