Related Experiment Video
Updated: Aug 10, 2026

Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood
Published on: October 12, 2012
Toxicity of plasma from hemodialysis patients treated with heparin or prostacyclin
Abstract:
Hemodialysis was performed in 6 uremic patients with either a bolus dose of 5 000 IU heparin or prostacyclin at a constant infusion rate of 5 ng/kg/min. Clinical data, plasma triglycerides (TG), free fatty acids (FFA), platelet aggregation, white blood cell count and plasma toxicity were measured prior to and during both procedures. No serious side-effects were recorded. Heparin induced a fall in plasma TG, a rise in FFA and increased plasma toxicity. Prostacyclin infusion had no effect on these parameters. During both tests a marked drop in white blood cell count was found 15 min after the start of hemodialysis. During heparin dialysis no clotting was observed in the extracorporeal circuit. During prostacyclin dialysis clotting was observed at the venous line in three cases.
More Related Videos
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists
These agonists bind to the IPR receptor situated on the plasma membrane of the pulmonary artery smooth muscle cells. This binding triggers a cascade of reactions known as the GS-AC-cAMP-PKA pathway. This pathway results in the relaxation of smooth muscle...
Drug toxicity: Idiosyncratic Reactions
Drug toxicity: Drug–Drug Interaction
Venous Thrombosis III: Interprofessional Care
Hemodialysis II: Procedure and Complications