Related Experiment Video
Updated: Aug 17, 2026

Colorimetric Paper-based Detection of Escherichia coli, Salmonella spp., and Listeria monocytogenes from Large Volumes of Agricultural Water
Published on: June 9, 2014
Evaluation of m-T7 agar as a fecal coliform medium
Abstract:
m-T7 agar, designed to improve recoveries of injured total coliforms, was evaluated for its effectiveness as a fecal coliform medium. The time and temperature of preincubation were found to be crucial to the optimal recovery of fetal coliforms. Isolation rates for fecal coliforms on m-T7 agar from sewage effluents were the highest when plates were preincubated at 37 degrees C for 8 h before transfer to 44.5 degrees C for 12 h. The medium was found to produce consistently higher fecal coliform counts than all the other methods tested. Recoveries were 3.1 times greater than the standard m-FC method and 1.7 times greater than the two-layer enrichment, temperature acclimation procedure. Verification rates for fecal coliforms isolated on m-T7 agar averaged 89.0%, whereas verification rates for m-FC agar averaged only 82.8%. Both media isolated similar fecal coliform populations. The advantages of a single medium, highly effective for the isolation of both total and fecal coliforms, are discussed.
Insights
m-T7 agar significantly improves fecal coliform recovery from sewage, outperforming standard methods. Optimal preincubation conditions enhance isolation rates for accurate water quality monitoring.
Area of Science:
- Environmental microbiology
- Water quality analysis
- Microbial detection methods
Background:
- Traditional methods for detecting coliforms can struggle with injured cells.
- There is a need for improved media to accurately quantify fecal coliforms in environmental samples.
Purpose of the Study:
- To evaluate m-T7 agar as an effective medium for fecal coliform isolation.
- To determine optimal preincubation conditions for fecal coliform recovery on m-T7 agar.
Main Methods:
- m-T7 agar was tested against standard methods (m-FC) and a two-layer enrichment procedure.
- Sewage effluents were used as sample matrices.
- Isolation and verification rates were compared under various preincubation times and temperatures.
Main Results:
- m-T7 agar yielded significantly higher fecal coliform counts than other methods (3.1x greater than m-FC).
- Optimal recovery was achieved with preincubation at 37°C for 8 hours, followed by 44.5°C for 12 hours.
- Verification rates for m-T7 agar (89.0%) were higher than for m-FC agar (82.8%).
Conclusions:
- m-T7 agar is a highly effective medium for isolating fecal coliforms from sewage.
- The optimized preincubation protocol enhances the sensitivity and accuracy of fecal coliform detection.
- m-T7 agar offers advantages for simultaneous isolation of total and fecal coliforms.

