Related Experiment Video
Updated: Aug 9, 2026

Selective Labelling of Cell-surface Proteins using CyDye DIGE Fluor Minimal Dyes
Published on: November 26, 2008
Glycoproteins of the chromaffin granule membrane: separation by two-dimensional electrophoresis and identification by
Abstract:
The proteins of highly purified chromaffin-granule membranes were separated by one- or two-dimensional electrophoresis, then transferred to nitrocellulose sheets; glycosylation was investigated by binding of several different radioiodinated lectins. Over 20 different glycosylated components were identified; comparison with mitochondrial and microsomal fractions suggested that most of the major glycoproteins are genuine components of the chromaffin granule membrane, rather than contaminants originating in other organelles. Two-dimensional electrophoresis revealed heterogeneity within several of the glycoproteins, and this is ascribed to differences in the state of glycosylation, on the basis of shifts in electrophoretic mobility produced by treatment with neuraminidase. Neuraminidase treatment of chromaffin granule membranes also enhances the binding of many lectins. The identities of the lectin-binding bands are discussed: neither cytochrome b561 nor the F1-like ATPase appears to be glycosylated. Chromogranin A, although a glycoprotein, does not bind any of the lectins tested, but a number of concanavalin-A binding proteins, as well as dopamine beta-hydroxylase, are present in the chromaffin granule lysate.
More Related Videos
Related Concept Videos
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Affinity Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

