Related Experiment Video
Updated: Aug 14, 2026

Electrophysiology on Isolated Brainstem-spinal Cord Preparations from Newborn Rodents Allows Neural Respiratory Network Output Recording
Published on: November 19, 2015
Rebreathing characteristics of the Bain circuit. An experimental and theoretical study
Abstract:
The Bain circuit was studied in a model lung on the assumption that, in addition to the ratio of fresh gas flow to total ventilation (VFG/VE), different time fractions of the respiratory cycle might influence rebreathing. We found that the time fraction for active expiration (FEt) governed rebreathing for each VFG/VE value. With FEt as an independent variable, a theoretical formula was derived for rebreathing. Rearranging this formula made it possible to calculate the necessary increase in ventilation to keep end-tidal carbon dioxide constant for each VFG/VE. Thus, at a fresh gas flow of 70 ml kg-1 min-1, VI has to be increased 2.6 times. For spontaneously breathing patients inhalation anaesthetics that do not depress carbon dioxide sensitivity seem to be better suited to use in the Bain circuit. The FECO2 can then be kept constant through increased ventilation in spite of the concomitant increase in rebreathing.
More Related Videos
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
05:45Experimental Approach to Examine Leptin Signaling in the Carotid Bodies and its Effects on Control of Breathing
Published on: October 25, 2019
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Design Example: Frog Muscle Response
When the switch connecting the RL circuit is closed, a brief muscle contraction is observed. This is because, at a steady state, the inductor acts like a short circuit,...
Other Factors Affecting Respiration Centers
However, the ability to hold one's breath voluntarily is not limitless. When the CO2 concentration in the blood reaches a critical level,...