Related Experiment Videos
[Electrocardiographic study of left ventricular performance in normal pregnancy]
This study was undertaken to determine the changes of left ventricular function during normal pregnancy. Fifteen women aged 23 to 36 years old were studied by M mode and 2D echocardiography at 3, 6 and 9 months and during the post partum period (30 days). The M mode recordings were analysed on an ID.01 computer. The principal parameters rose significantly from the 3rd to the 9th month, and then fell during the post partum period: heart rate, 73 +/- 5 to 80 +/- 9 and then to 70 +/- 8 beats/min: LV end diastolic parameter 46 +/- 2 to 49 +/- 3 mm: LV end diastolic volume 102 +/- 16 to 120 +/- 30 and then 102 +/- 22 cm3; stroke volume: 72 +/- 15 to 87 +/- 25 and then to 70 +/- 16 ml; cardiac output: 5.6 +/- 1.2 to 7.1 +/- 2.3 and then to 5.0 +/- 1.4 l/min; cardiac index: 3.5 +/- 0.7 to 4.1 +/- 1.3 and then to 3.0 +/- 0.8 l/min/m2; LV mass: 69 +/- 14 to 91 +/- 39 and then to 82 +/- 27 g; the ratio of mass/volume also increased from 0.97 +/- 0.14 to 1.10 +/- 0.5. On the other hand, the following parameters did not change significantly: LV end systolic diameter: 30 +/- 3 to 31 +/- 3 and then to 30 +/- 4 mm; ejection fraction: 0.70 +/- 0.72 and then to 0.68; LV fractional shortening: 34 +/- 5 to 36 +/- 5 and then 33 +/- 6; velocity of circumferential fibre shortening: 1.2 +/- 0.2 to 1.2 +/- 0.1 and then 1.1 +/- 0.2 circ/s.(ABSTRACT TRUNCATED AT 250 WORDS)
This study was undertaken to determine the changes of left ventricular function during normal pregnancy. Fifteen women aged 23 to 36 years old were studied by M mode and 2D echocardiography at 3, 6 and 9 months and during the post partum period (30 days). The M mode recordings were analysed on an ID.01 computer. The principal parameters rose significantly from the 3rd to the 9th month, and then fell during the post partum period: heart rate, 73 +/- 5 to 80 +/- 9 and then to 70 +/- 8 beats/min: LV end diastolic parameter 46 +/- 2 to 49 +/- 3 mm: LV end diastolic volume 102 +/- 16 to 120 +/- 30 and then 102 +/- 22 cm3; stroke volume: 72 +/- 15 to 87 +/- 25 and then to 70 +/- 16 ml; cardiac output: 5.6 +/- 1.2 to 7.1 +/- 2.3 and then to 5.0 +/- 1.4 l/min; cardiac index: 3.5 +/- 0.7 to 4.1 +/- 1.3 and then to 3.0 +/- 0.8 l/min/m2; LV mass: 69 +/- 14 to 91 +/- 39 and then to 82 +/- 27 g; the ratio of mass/volume also increased from 0.97 +/- 0.14 to 1.10 +/- 0.5. On the other hand, the following parameters did not change significantly: LV end systolic diameter: 30 +/- 3 to 31 +/- 3 and then to 30 +/- 4 mm; ejection fraction: 0.70 +/- 0.72 and then to 0.68; LV fractional shortening: 34 +/- 5 to 36 +/- 5 and then 33 +/- 6; velocity of circumferential fibre shortening: 1.2 +/- 0.2 to 1.2 +/- 0.1 and then 1.1 +/- 0.2 circ/s.(ABSTRACT TRUNCATED AT 250 WORDS)