Related Experiment Video
Updated: Aug 4, 2026

Measurement of Carotenoids in Perifovea using the Macular Pigment Reflectometer
Published on: January 29, 2020
Detection of carotenoids in blood donors taking Orobronze: a cautionary note
Abstract:
During the summer, plasma samples from eight blood donors at this transfusion centre were found to have a bright orange colour. All donors appeared to be healthy and haematological tests showed no abnormality. Extracts of lipid from the plasma revealed the presence of the carotenoid canthaxanthin and other carotenoid metabolites which were identified by thin-layer chromatography and high-pressure liquid chromatography, light absorbtion and mass spectrometry. On questioning the donors it was found that they had been taking a course of 'Orobronze' (an oral 'bronzing' treatment containing canthaxanthin). Canthaxanthin was still detectable in the plasma several months after the donors had ceased taking the capsules. At present it seems that there would be no deleterious effects on healthy individuals taking orobronze. The full implications of the presence of canthaxanthin in plasma transfused to patients do, however, require further investigation of carotenoid metabolism in man.
More Related Videos
06:19Evaluation of Oxidative Stress in Biological Samples Using the Thiobarbituric Acid Reactive Substances Assay
Published on: May 12, 2020
05:03Quantitative Analysis of Dietary Vitamin A Metabolites in Murine Ocular and Non-Ocular Tissues Using High-Performance Liquid Chromatography
Published on: December 27, 2024