Related Experiment Videos
Laparoscopic sterilization with electrocautery, silastic bands and spring-loaded clips: report of our experience with
European Journal of Obstetrics, Gynecology, and Reproductive Biology
|February 1, 1980
Abstract:
A comparative study was carried out in 790 women undergoing one of the 3 most frequently used laparoscopic sterlization techniques: high-frequency unipolar electrocoagulation of the tubes, application of silastic rings or spring-loaded clips to the tubes. The technical problems and per- and postoperative (early) complications are assessed. The use of high-frequency unipolar current has been superseded by today's mechanical and non-electrical sterilization methods. The spring-loaded clip method appears to be a sterilization technique with a minimum of severe complications, and theoretically the greatest chances for possible refertilization.
Keywords:
BleedingBurnsClipsComparative StudiesDiseasesElectrocoagulationEquipment And SuppliesFamily PlanningFemale SterilizationGynecologic SurgeryPerforationsResearch MethodologyReversible SterilizationSigns And SymptomsSilastic RingSterilization ReversalSterilization, SexualStudiesSurgeryTreatmentTubal OcclusionTubal Reanastomosis