Electrocardiogram computer analysis. practical value of the IBM Bonner-2 (V2 MO) program
Abstract:
One thousand ECGs were selected from those taken from an adult population and analyzed by three cardiologists to assess the performance of the IBM Bonner-2 (V2 MO) program. The sample included 200 ECGs with 248 myocardial infarctions, 200 with conduction abnormalities, 100 with ventricular hypertrophy, 300 normals and 200 with electronic pacemakers. In the MI group, there was a total sensitivity of the program with respect to the readers of 88% (218/248) with 19 (8%) program errors and 90% (248/275) specificity. In 53 ECGs with two MI statements, the sensitivity was 89% (47/53). The sensitivity in conduction abnormalities was 93.4% (183/196) with 98.7% specificity (800/810). The sensitivity in LVH was 90% (74/81) and in RVH 83% (5/6). Among the normals, the specificity was 98.6% (289/293). The sensitivity to PVCs was 84% (56/67), to atrial fibrillation 87% (48/55), to SVCs 58.6% (17/29) and to electronic pacemakers 65% (127/196). Recognizing the limitations of this type of analysis, this study indicates that the V2 MO version compares favorably with the earlier versions of the same program and is a valuable aid in ECG interpretation with rapid acceptance by physicians.
Related Concept Videos
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias


