Related Experiment Video
Updated: Sep 4, 2026

Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique
Published on: May 3, 2015
Determination of fluoride in fluoride tablets and solutions by ion-selective electrode: collaborative study
Abstract:
A proposed method using the fluoride (F) ion-selective electrode has been developed for determining the fluoride ion concentration in tablets and solutions containing sodium fluoride. The method has been subjected to collaborative study. Eight samples consisting of 2 authentic fluoride solutions, 2 commercial fluoride solutions, and 4 commercial fluoride tablets were sent to each of 11 collaborators together with a copy of the method. Single assays on the authentic fluoride solutions known to contain 1 mg F/5 mL were performed with average recoveries of 99.5 and 99.6% and relative coefficients of variation (CV) of 2.11 and 1.91%, respectively. Single assays of 2 commercial fluoride solutions declared at 1 mg F/5 mL gave mean values of 0.994 and 0.990 mg and relative CV values of 1.88 and 2.36%, respectively. Single assays of 2 commercial fluoride tablet preparations declared at 0.5 mg F gave mean values of 0.485 and 0.478 mg and relative CV values of 3.12 and 3.71%, respectively. Single assays of 2 commercial fluoride tablet preparations declared at 1 mg F gave mean values of 0.991 and 0.981 mg and relative CV values of 2.99 and 2.85%, respectively. The method has been adopted official first action.
More Related Videos
09:24Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Precipitation Reactions
Factors Affecting Solubility
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
EDTA: Indirect and Alkalimetric Titration