A critical view of the utility of positive controls in a test battery

Neurobehavioral Toxicology and Teratology
|March 1, 1984
PubMed

Related Concept Videos

Controls in Experiments01:13

Controls in Experiments

When conducting an experiment, it is crucial to have control to reduce bias and accurately measure the dependent variables. It also marks the results more reliable. Controls are elements in an experiment that have the same characteristics as the treatment groups but are not affected by the independent variable. By sorting these data into control and experimental conditions, the relationship between the dependent and independent variables can be drawn. A randomized experiment always includes a...
DC Battery01:21

DC Battery

A conductor needs to be a component of a path that creates a closed loop or full circuit to have a continuous current flowing through it. A current starts to flow if an electric field is created inside an isolated conductor that is not part of a full circuit. The conductor quickly develops a net positive charge at one end and a net negative charge at the other. These charges generate an electric field opposite the direction of the applied electric field, which reduces the current. Eventually,...
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential ensures...
Controlled-Current Coulometry: Coulometric Titration01:18

Controlled-Current Coulometry: Coulometric Titration

Coulometric titrations are a form of titrimetric analysis where the reagent is generated electrically, and its amount is evaluated based on current and generating time. The electron serves as the standard reagent. The procedure is similar to conventional titrations, such as endpoint detection.
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
Sensitivity, Specificity, and Predicted Value01:13

Sensitivity, Specificity, and Predicted Value

In healthcare diagnostics, laboratory tests play a crucial role in identifying and diagnosing a wide range of medical conditions. However, interpreting test results is not always straightforward. An abnormal test result does not always confirm the presence of a disease, just as a normal result does not guarantee its absence. To assess the reliability of these diagnostic tools, healthcare practitioners rely on two key statistical indicators: sensitivity and specificity.
Sensitivity is the...