Abstract:
Five patients, who were treated in a special ward for burns were followed by continuous intra-arterial pO2 monitoring for a total of 1612 h (range 13-604 h). The pao2 catheter electrodes used were surface-heparinized, and inserted either in the radial or the femoral artery. Some electrodes were accidentally withdrawn. Recalibration was performed for two of the 10 electrodes used. These electrodes presented a changed sensitivity after heavy stretching of the sensor during the nursing. The sensitivity of one of these electrodes was altered downwards and the other one upwards. After recalibration the pao2 electrodes presented accurate values for the rest of the monitoring period. Without compensation for drift, the pao2 electrode readout was compared to the results of traditional blood-gas analysis, which served as a reference. The regression function found was y = -0.62 + 1.04 chi (r = 0.93, SD = 1.40, n = 60). The blood flow velocity around some of the pao2 electrodes was studied by the pulsed Doppler technique. There was no influence of the surface-heparinized pao2 electrode on the femoral artery blood flow velocity as compared to the contralateral, non-catheterized femoral artery. The blood flow velocity proximal to a traditional radial artery catheter was compared to the flow velocity in the contralateral radial artery containing a surface-heparinized pao2 electrode. The surface-heparinized electrode did not decrease the mean flow velocity in contrast with the traditional radial artery catheter, which had to be withdrawn after 8 days because of clotting. The surface-heparinized catheter electrode was still monitoring pao2 accurately after 25 days in the artery, which was the longest period studied for a particular sensor.
More Related Videos
07:48Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock
Published on: October 28, 2022
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...