[Doppler pulse and interventricular communication].

M A Cherifi, I Oberhänsli, B Friedli

    Helvetica Paediatrica Acta
    |December 1, 1984
    PubMed
    Summary

    Pulsed Doppler ultrasound is more sensitive than 2D echocardiography for diagnosing ventricular septal defects (VSD) in children. This non-invasive technique accurately detects VSDs, even small ones, and remains effective with other heart conditions.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Coarctation of the aorta: pre and postoperative evaluation with MRI and MR angiography; correlation with echocardiography and surgery.

    The international journal of cardiovascular imaging·2005
    Same author

    Balloon aortic valvoplasty in paediatric patients: progressive aortic regurgitation is common.

    Heart (British Cardiac Society)·2003
    Same author

    [Clinical course following partial cavo-pulmonary bypass: the Geneva experience from 1985 to 2000].

    Archives des maladies du coeur et des vaisseaux·2003
    Same author

    [False aneurysm complicating ligation of patent ductus arteriosus operated on successfully].

    Annales de cardiologie et d'angeiologie·2003
    Same author

    Effects of cisapride on ventricular depolarization-repolarization and arrhythmia markers in infants.

    Biology of the neonate·2001
    Same author

    Transcatheter occlusion of the patent ductus arteriosus with a single device technique: comparison between the Cook detachable coil and the Rashkind umbrella device.

    International journal of cardiology·2001

    Area of Science:

    • Pediatric Cardiology
    • Diagnostic Imaging
    • Echocardiography

    Background:

    • Ventricular septal defects (VSD) are common congenital heart abnormalities requiring accurate diagnosis.
    • Two-dimensional echocardiography (2D-echo) and pulsed Doppler are non-invasive methods used for VSD assessment.
    • Comparative diagnostic accuracy of these modalities, particularly in pediatric populations, warrants further investigation.

    Purpose of the Study:

    • To evaluate and compare the diagnostic accuracy of pulsed Doppler and 2D-echo in identifying VSD in children.
    • To determine the sensitivity of each imaging technique for detecting VSD, including smaller defects.

    Main Methods:

    • A study involving 32 children with suspected VSD.
    • Group I (17 children) had VSD confirmed by cardiac catheterization.
    • Group II (15 children) underwent non-invasive investigations only; both 2D-echo and pulsed Doppler were utilized.

    Main Results:

    • 2D-echo identified VSD in 82% of confirmed cases (Group I) and 73% of suspected cases (Group II).
    • Pulsed Doppler detected typical turbulent flow indicative of VSD in 100% of cases in both groups.
    • Pulsed Doppler demonstrated higher sensitivity, especially for small VSDs, compared to 2D-echo.

    Conclusions:

    • Pulsed Doppler ultrasound is a more sensitive diagnostic tool for VSD in children than 2D-echo.
    • The diagnostic accuracy of pulsed Doppler is maintained in the presence of associated cardiac malformations and pulmonary hypertension (unless shunt is reversed).
    • Pulsed Doppler is particularly valuable for detecting small VSDs.