External fixation of the pelvis.

H E Rubash, D C Mears

    Instructional Course Lectures
    |January 1, 1983
    PubMed
    Summary

    External fixation with a triangular frame stabilizes pelvic fractures, reducing hemorrhage and complications. This method allows early patient mobilization, improving outcomes and decreasing mortality.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Longitudinal changes in patient-reported outcome measures following total hip arthroplasty and predictors of deterioration during follow-up: a seven-year prospective international multicentre study.

    The bone & joint journal·2019
    Same author

    Side-to-side variation in normal femoral morphology: 3D CT analysis of 122 femurs.

    Orthopaedics & traumatology, surgery & research : OTSR·2016
    Same author

    Lengthening of an above-knee amputation by transposition of the ipsilateral tibia.

    Orthopedics·2014
    Same author

    Fat graft interposition: an adjunct to resection of calcaneonavicular bar: a case report.

    Orthopedics·2014
    Same author

    Plate fixation of tibial shaft fractures.

    Orthopedics·2014
    Same author

    In-vivo time-dependent articular cartilage contact behavior of the tibiofemoral joint.

    Osteoarthritis and cartilage·2010

    Area of Science:

    • Orthopedic Surgery
    • Trauma Management

    Background:

    • Pelvic fractures pose significant management challenges, particularly controlling severe intrapelvic hemorrhage.
    • Traditional methods often led to prolonged immobilization and associated complications.

    Purpose of the Study:

    • To evaluate a simplified external fixation protocol for pelvic ring fractures.
    • To assess the efficacy of a triangular frame system in managing pelvic fractures.

    Main Methods:

    • A protocol combining early external fixation with closed reduction was implemented.
    • A triangular frame system was utilized for pelvic ring stabilization.

    Main Results:

    • Significant reduction in intrapelvic hemorrhage was observed.
    • Early patient mobilization, including weight-bearing gait, was facilitated.
    • Late complications such as nonunion and malunion were largely avoided.
    • Reduced incidence of pulmonary, gastrointestinal, and urologic complications.

    Conclusions:

    • The triangular external fixation system offers adequate stability for pelvic ring fractures.
    • Early stabilization promotes pain reduction, early mobilization, and improved patient outcomes.
    • This approach decreases fracture-related morbidity and mortality.