Related Experiment Video
Updated: Aug 21, 2026

Characterization of Metabolic Status in Nonhuman Primates with the Intravenous Glucose Tolerance Test
Published on: November 13, 2016
Somatostatin-like immunoreactivity in rat blood. Characterization, regional differences, and responses to oral and
Somatostatin-like immunoreactivity (SLI) has been demonstrated by radioimmunoassay (RIA) in rat serum using an antiserum specific for somatostatin and cross-reacting maximally with the biologically important area on the peptide. The RIA has a sensitivity of 35 pg/ml. SLI dilutes in parallel with synthetic somatostatin standard in the RIA and shows characteristics similar to synthetic somatostatin on Sephadex G-25 (f) gel chromatography eluting largely as a single peak with 1 M acetic acid. Significant regional differences in serum SLI are present. A positive gradient was found in paired samples from aorta (mean+/-SEM, 0.304+/-0.024 ng/ml) and portal vein (0.495+/-0.047 ng/ml) consistent with the known presence of somatostatin in gut and pancreas, and a negative gradient was noted between paired samples from portal vein (0.523+/-0.076 ng/ml) and hepatic vein (0.290+/-0.048 ng/ml) indicating hepatic clearance. No significant differences were demonstrated between aorta and confluence of cerebral venous sinuses or between aorta and inferior vena cava (IVC). After intragastric glucose, a significant and marked elevation of portal SLI was observed, maximal at 5 min (0.416+/-0.137 vs. 1.55+/-0.30 ng/ml at 5 min). A significant biphasic elevation of portal SLI also occurred after intravenous glucose. After both routes of glucose administration, the patterns of portal SLI followed closely those of portal glucose and insulin. By contrast, IVC SLI failed to reflect these changes.Thus, SLI in the rat shows chromatographic similarity with synthetic somatostatin. Regional differences in serum levels are marked; the highest concentrations being found in the portal venous effluent of pancreas and gut. Furthermore, glucose causes elevation of portal SLI in a pattern similar to portal insulin and glucose and without concomitant elevation in IVC. This differential elevation of SLI after glucose is consistent with a hormonal action within the portal system as a direct effect of somatostatin on the liver has previously been demonstrated. In addition, the liver is important in the clearance of portal SLI, possibly to prevent extraportal effects in response to gut and pancreatic stimulation. Finally, it is clear that regional sampling of serum for SLI measurement may be critical in the investigation of the putative physiological roles for somatostatin.
Somatostatin-like immunoreactivity (SLI) has been demonstrated by radioimmunoassay (RIA) in rat serum using an antiserum specific for somatostatin and cross-reacting maximally with the biologically important area on the peptide. The RIA has a sensitivity of 35 pg/ml. SLI dilutes in parallel with synthetic somatostatin standard in the RIA and shows characteristics similar to synthetic somatostatin on Sephadex G-25 (f) gel chromatography eluting largely as a single peak with 1 M acetic acid. Significant regional differences in serum SLI are present. A positive gradient was found in paired samples from aorta (mean+/-SEM, 0.304+/-0.024 ng/ml) and portal vein (0.495+/-0.047 ng/ml) consistent with the known presence of somatostatin in gut and pancreas, and a negative gradient was noted between paired samples from portal vein (0.523+/-0.076 ng/ml) and hepatic vein (0.290+/-0.048 ng/ml) indicating hepatic clearance. No significant differences were demonstrated between aorta and confluence of cerebral venous sinuses or between aorta and inferior vena cava (IVC). After intragastric glucose, a significant and marked elevation of portal SLI was observed, maximal at 5 min (0.416+/-0.137 vs. 1.55+/-0.30 ng/ml at 5 min). A significant biphasic elevation of portal SLI also occurred after intravenous glucose. After both routes of glucose administration, the patterns of portal SLI followed closely those of portal glucose and insulin. By contrast, IVC SLI failed to reflect these changes.Thus, SLI in the rat shows chromatographic similarity with synthetic somatostatin. Regional differences in serum levels are marked; the highest concentrations being found in the portal venous effluent of pancreas and gut. Furthermore, glucose causes elevation of portal SLI in a pattern similar to portal insulin and glucose and without concomitant elevation in IVC. This differential elevation of SLI after glucose is consistent with a hormonal action within the portal system as a direct effect of somatostatin on the liver has previously been demonstrated. In addition, the liver is important in the clearance of portal SLI, possibly to prevent extraportal effects in response to gut and pancreatic stimulation. Finally, it is clear that regional sampling of serum for SLI measurement may be critical in the investigation of the putative physiological roles for somatostatin.
More Related Videos
08:13Study of In Vivo Glucose Metabolism in High-fat Diet-fed Mice Using Oral Glucose Tolerance Test (OGTT) and Insulin Tolerance Test (ITT)
Published on: January 7, 2018
07:30Homogeneous Time-resolved Förster Resonance Energy Transfer-based Assay for Detection of Insulin Secretion
Published on: May 10, 2018
Related Concept Videos
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are co-secreted in...
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by the...
Hypoglycemia and Glucagon