Isomeric purity and supersaturation of iopamidol
The British Journal of Radiology
|October 1, 1983
Abstract:
We have found that iopamidol 370 mg I/ml solutions may be greatly supersaturated and iopamidol 300 mg I/ml solutions slightly supersaturated at 4 degrees C and at 25 degrees C. The solubility and degree of supersaturation probably depend on the isomeric purity of the preparation. Some possible implications are discussed.
Related Concept Videos
Expressing Solution Concentration
A solute is a component of a solution that is typically present at a much lower concentration than the solvent. Solute concentrations are often described with qualitative terms such as dilute (of relatively low concentration) and concentrated (of relatively high concentration).
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
Stereoisomerism
Isomerism in Complexes
Isomers are different chemical species that have the same chemical formula.
Transition metal complexes often exist as geometric isomers, in which the same atoms are connected through the same types of bonds but with differences in their orientation in space. Coordination complexes with two different ligands in the cis and trans positions from a ligand of interest form isomers. For example, the octahedral [Co(NH3)4Cl2]+ ion has two isomers (Figure 1) In the cis...
Isomers are different chemical species that have the same chemical formula.
Transition metal complexes often exist as geometric isomers, in which the same atoms are connected through the same types of bonds but with differences in their orientation in space. Coordination complexes with two different ligands in the cis and trans positions from a ligand of interest form isomers. For example, the octahedral [Co(NH3)4Cl2]+ ion has two isomers (Figure 1) In the cis...
Basicity of Heterocyclic Aromatic Amines
Heterocyclic amines, where the N atom is a part of an alicyclic system, are similar in basicity to alkylamines. Interestingly, the heterocyclic amine having a nitrogen atom as part of an aromatic ring has much less basicity than its corresponding alicyclic counterpart. For this reason, as presented in Figure 1, piperidine (pKb = 2.8) is significantly more basic than pyridine (pKb = 8.8).
Redox Titration: Iodimetry and Iodometry
Iodometry and iodimetry are analytical methods used to determine the concentration of oxidizing or reducing agents using iodine. In iodometric titrations, the oxidizing analyte solution is usually acidified and treated with an excess of iodide ions, which generates an equivalent amount of iodine in equilibrium with triiodide. The released iodine is subsequently titrated directly against a standardized reducing agent. As the dilute iodine color becomes pale yellow, a few drops of freshly...
Precipitation Processes
The experimental conditions in a gravimetric analysis should be optimized to maximize the particle size and purity of the obtained precipitate. Ideally, the concentration of the precipitating reagent should be low with effective stirring to maintain low relative supersaturation for the growth of large crystals. In homogeneous precipitation, the precipitant is slowly generated by a chemical reaction in the solution to avoid local reagent excesses. For example, urea decomposes gradually to...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...