Ultrasonic assessment of the St. Jude prosthetic valve: M mode, two-dimensional, and Doppler echocardiography
Abstract:
To determine whether the flow characteristics of aortic and mitral St. Jude Medical valves could be defined noninvasively, we analyzed Doppler transprosthetic flow velocity spectra in 23 relatively asymptomatic patients. Results were interpreted in the framework of M mode and two-dimensional echocardiographic data and were compared with Doppler transvalvular flow velocity spectra from native valves of healthy subjects. Although the morphologic characteristics of Doppler spectra were similar, peak and mean transprosthetic mitral flow velocities were higher than values obtained across native valves (1.38 +/- 0.3 m/sec and 0.73 +/- 0.1 m/sec vs 0.78 +/- 0.1 m/sec and 0.35 +/- 0.06 m/sec, respectively; p less than .001). However, calculated pressure half-times were not different (61.2 +/- 16.9 msec vs 57.2 +/- 13.2 msec; p greater than .05) and calculated transprosthetic mitral gradients were small (2.3 +/- 0.9 mm Hg). Similarly, the morphologic characteristics of aortic Doppler flow spectra in St. Jude and native valves were analogous. However, prosthetic valves exhibited higher peak and mean velocities (p less than .01) and slightly prolonged time-to-peak flow (p = .02). M mode and two-dimensional studies did not show useful quantitative measures of prosthetic function and did not demonstrate evidence of paravalvular leaks, which were detected in four cases by Doppler techniques. Thus Doppler echocardiography provides quantitative information about transprosthetic flow characteristics in patients with implanted St. Jude valves and is useful in identifying patients with prosthetic dysfunction.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies II: Ultrasonography