Related Experiment Video
Updated: Oct 4, 2026

Measurement of Vibration Detection Threshold and Tactile Spatial Acuity in Human Subjects
Published on: September 1, 2016
Availability of temperature sense indices for diagnosis of vibration disease
Abstract:
The correlation between stages of vibration disease and hypesthesia of temperature sense detected with our thermo-esthesiometer was analyzed. We measured the warm and cool thresholds among operators (644 males) in three occupational categories with vibration exposure from hand-held vibratory tools, such as grinder, drill, sander, impact-wrench, bush-cutter and chain-saw. Through the examination of the relationship between the temperature threshold and the stage of vibration disease, the following was revealed: The warm sense threshold elevated parallel with the aggravation of vibration disease, although the skin temperature had no change or reduction. The hypesthesia of the cool sense threshold appeared in serious cases of vibration disease. This abnormality of the cool sense indicated a more intensive disorder than that detected by the warm sense abnormality. The width of the neutral zone between the warm and cool thresholds of the intact subjects was 6.6 degrees C +/- 3.8 C degrees. This neutral zone was enlarged with the aggravation of the vibration disease. Data also showed that the measurements of temperature sense threshold should be carried out under standardized room temperature.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...