Related Experiment Videos
Intensity discrimination as a function of level and frequency and its relation to high-frequency hearing
Abstract:
This paper examines how intensity discrimination depends on the test frequency, the level, and the subjects's high-frequency hearing. Three experiments were performed. In the first experiment, intensity discrimination of pulsed tones was measured as a function of level at 1 and 14 kHz in five listeners. Results show less deviation from Weber's law at 14 kHz than at 1 kHz. In the second experiment, intensity discrimination was measured for a 1-kHz tone at 90-dB SPL as a function of the cutoff frequency of a high-pass masking noise in two listeners. Results show that the audibility of very high frequencies is important for frequency discrimination at 1 kHz. The DL increased by a factor between 1.5 and 2.0 as the cutoff frequency of the noise was lowered from 19 to 6 kHz. In the third experiment, thresholds from 6 to 20 kHz and intensity discrimination for a 1-kHz tone was measured in 12 listeners. Results show that the DLs at 80-dB SPL are correlated with the ability to hear very high frequencies. Results of all three experiments are consistent with the multiband version of the excitation-pattern model for intensity discrimination [Florentine and Buus, J. Acoust. Soc. Am. 70, 1646-1654 (1981)].