An equivalent squares template.

I I Rosen, R G Lane, H L Van Camp

    Medical Physics
    |November 1, 1983
    PubMed
    Summary
    This summary is machine-generated.

    A new template accurately calculates equivalent squares for irregular radiation fields, offering a faster and more precise manual method than area-perimeter ratios.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Wave-front reconstruction using a Shack-Hartmann sensor.

    Applied optics·2010
    Same author

    Phase retrieval with prior information.

    Journal of the Optical Society of America. A, Optics and image science·2008
    Same author

    Modeling scintillation from an aperiodic Kolmogorov phase screen.

    Applied optics·2008
    Same author

    Analysis of optimal centroid estimation applied to Shack-Hartmann sensing.

    Applied optics·2008
    Same author

    Fast simulation of a kolmogorov phase screen.

    Applied optics·2008
    Same author

    Phase I study of concomitant gemcitabine and IMRT for patients with unresectable adenocarcinoma of the pancreatic head.

    International journal of gastrointestinal cancer·2003
    Same journal

    Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

    Medical physics·2026
    Same journal

    Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

    Medical physics·2026
    Same journal

    Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

    Medical physics·2026
    Same journal

    Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

    Medical physics·2026
    Same journal

    Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

    Medical physics·2026
    Same journal

    Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

    Medical physics·2026
    See all related articles

    Area of Science:

    • Medical Physics
    • Radiation Oncology

    Background:

    • Accurate calculation of equivalent squares is crucial for radiation therapy dose calculations.
    • Existing manual methods may lack precision for irregularly shaped fields.

    Purpose of the Study:

    • To introduce and validate a novel template-based method for calculating equivalent squares of irregularly shaped radiation fields.
    • To compare the accuracy and efficiency of the template method against established computational and manual techniques.

    Main Methods:

    • Development of a template for calculating equivalent squares through scatter summation.
    • Comparison of template-derived equivalent squares and tumor doses with a computer program.
    • Comparison with area-perimeter ratio methods for computing equivalent squares.

    Related Experiment Videos

    Main Results:

    • The template method demonstrated good agreement with computer program calculations for equivalent squares and tumor doses (within 0.8%).
    • The template method showed consistently better accuracy than area-perimeter ratio methods.
    • Manual computation time for highly irregular fields was comparable to other methods (3-10 minutes).

    Conclusions:

    • The template method provides an accurate and efficient manual approach for determining equivalent squares of irregular radiation fields.
    • This method offers improved accuracy over traditional area-perimeter ratio techniques, particularly for complex field shapes.