Related Experiment Videos

Nosocomial infections by chlorhexidine solution contaminated with Pseudomonas pickettii (Biovar VA-I)

The Journal of Infection
|November 1, 1983
PubMed

Insights

Pseudomonas pickettii bloodstream infections in a cardiac ICU were linked to contaminated chlorhexidine solutions. Preventing the use of contaminated bidistilled water stopped further cases, highlighting the importance of water purity in healthcare settings.

Area of Science:

  • Infectious Diseases
  • Hospital Epidemiology
  • Microbiology

Background:

  • Cardiac intensive care units (ICUs) are high-risk environments for healthcare-associated infections.
  • Venous catheterization is a common procedure associated with potential infectious complications.

Observation:

  • Six patients in a cardiac ICU developed Pseudomonas pickettii (biovar VA-I) septicemia over 10 days following venous catheter insertion.
  • The causative organism, Pseudomonas pickettii, was isolated from chlorhexidine solutions used in patient care.

Findings:

  • The Pseudomonas pickettii infections were traced to the use of 0.05% chlorhexidine ('Hibitane') solutions prepared with contaminated bidistilled water.
  • Implementing a prohibition on the use of this contaminated water source led to the cessation of new infection cases.

Implications:

  • This outbreak underscores the critical role of water quality in the preparation of antiseptic solutions within healthcare facilities.
  • Strict control over water sources and preparation protocols for medical solutions is essential to prevent Pseudomonas infections in vulnerable patient populations.
  • Enhanced surveillance and microbial testing of hospital water systems and solutions are recommended to prevent similar outbreaks.