Related Experiment Videos
High-performance liquid chromatographic methods for the analysis of human parathyroid hormone in reference standards,
Abstract:
Reversed-phase high-performance liquid chromatography (RP-HPLC) has been used to fractionate human parathyroid hormone (hPTH) from a variety of natural sources and to compare it with synthetic hPTH and hPTH fragments. Multiple radioimmunoassay systems for amino, mid and carboxyl regions of hPTH were used to monitor various preparations of hPTH previously prepared by conventional methods and ampouled in nanogram amounts for reference standard and reagent purposes. Results confirmed that they were free of detectable cleavage products, but showed that the intact hPTH comprised three or four closely associated components. A similar pattern of heterogeneity was obtained when hPTH was extracted from stored human parathyroid adenomata by a simple rapid HPLC bulk fractionation method. Comparison with synthetic 1-84 hPTH and modification of sample handling to minimize oxidative conditions, indicate that some of these components are probably intermediate oxidation products. A number of less hydrophobic components, with carboxyl region immunoreactivities, were obtained from the individual adenoma samples, human parathyroid cyst fluid, ampouled samples of human adenoma tissue culture medium, and secondary hyperparathyroid plasma ultrafiltrate when they were fractionated by RP-HPLC. The results strongly suggest that the biological degradation of hPTH is more complex than generally believed, and that RP-HPLC offers a new dimension in its analysis.