A new A-scan ultrasonoscope.

N R Bronson

    Annals of Ophthalmology
    |May 1, 1984
    PubMed
    Summary
    This summary is machine-generated.

    A novel A-mode biometry system features a soft transducer to prevent corneal indentation and improve axial length measurement accuracy. Its microprocessor ensures correct axial alignment, reducing user error for reliable eye measurements.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Capsular forceps for extraocular extraction: a new use for an old instrument (newly designed).

    Ophthalmic surgery·1985
    Same author

    Ultrasonography for patients with uveitis.

    Transactions of the ophthalmological societies of the United Kingdom·1976
    Same author

    Real-time color B-scan ultrasonography.

    Journal of clinical ultrasound : JCU·1975
    Same author

    Contact B-scan ultrasonography: clinicopathological correlations.

    Annals of ophthalmology·1975
    Same author

    A simple B-scan ultrasonoscope.

    Bibliotheca ophthalmologica : supplementa ad ophthalmologica·1975
    Same author

    Ophthalmic contact B-scan ultrasonography. A practical clinical tool.

    Archives of ophthalmology (Chicago, Ill. : 1960)·1974
    Same journal

    Ocular toxicity of systemic chemotherapy with megadoses of carmustine and mitomycin.

    Annals of ophthalmology·1994
    Same journal

    Congenital intrastromal epithelial cyst of the iris.

    Annals of ophthalmology·1994
    Same journal

    Diagnosis and treatment of orbital hemorrhagic lesions.

    Annals of ophthalmology·1994
    Same journal

    Clinical features of toxoplasmic retinochoroiditis in patients with acquired immunodeficiency syndrome.

    Annals of ophthalmology·1994
    Same journal

    The closed chamber slipping suture technique for iris repair.

    Annals of ophthalmology·1994
    Same journal

    The effect of gravity on the amplitude of accommodation.

    Annals of ophthalmology·1994
    See all related articles

    Area of Science:

    • Ophthalmology
    • Biomedical Engineering
    • Medical Devices

    Background:

    • Accurate axial length measurement is crucial for refractive error correction.
    • Traditional A-mode biometry systems risk corneal indentation, leading to measurement inaccuracies.
    • User skill variability can impact the reliability of existing A-scan devices.

    Purpose of the Study:

    • To introduce a new A-mode biometry system designed for enhanced accuracy in axial length measurements.
    • To reduce the incidence of corneal indentation during ocular biometry.
    • To minimize user-dependent errors in obtaining axial alignment for eye measurements.

    Main Methods:

    • Development of an A-mode biometry system utilizing a soft-membrane transducer.
    • Integration of a microprocessor for automated echo pattern evaluation and axial alignment confirmation.

    Related Experiment Videos

  • Testing the system's usability and accuracy with both physicians and technicians.
  • Main Results:

    • The soft-membrane transducer significantly reduces the risk of corneal indentation.
    • The microprocessor-based system effectively identifies and confirms axial alignment.
    • The new A-scan system demonstrates minimal user skill requirement and consistent performance.

    Conclusions:

    • The developed A-mode biometry system offers a more accurate and reliable method for axial length measurement.
    • The soft transducer and automated alignment verification address key limitations of previous systems.
    • This technology has the potential to improve diagnostic accuracy and streamline ophthalmic procedures.