Related Experiment Videos
A stable isotope dilution assay for disopyramide and its [13C, 15N]labelled analogue in biological fluids
Biomedical Mass Spectrometry
|February 1, 1980
Abstract:
The mass spectra of disopyramide phosphate and two stable isotopically labelled analogues have been obtained using electron impact and chemical ionization. The low isotopic purity of [13C, 15N)disopyramide phosphate was shown to be due to the low isotopic purity of the 15N label. A stable isotope dilution assay for disopyramide and [13C, 15N]disopyramide in biological fluids has been developed using [2H14]disopyramide phosphate as the internal standard. This assay will be used to analyse samples obtained after the co-administration of disopyramide phosphate intravenously and [13C, 15N]disopyramide phosphate orally to several animal species.