Mean energy in electron beams.

P Andreo, A Brahme

    Medical Physics
    |September 1, 1981
    PubMed
    Summary
    This summary is machine-generated.

    This study investigates electron beam energy variations using Monte Carlo simulations. Results show minimal impact on absorbed dose profiles, validating current dosimetry assumptions.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Determination of consensus k <sub>Q</sub> values for megavoltage photon beams for the update of IAEA TRS-398.

    Physics in medicine and biology·2020
    Same author

    Correction factors for ionization chamber measurements with the 'Valencia' and 'large field Valencia' brachytherapy applicators.

    Physics in medicine and biology·2018
    Same author

    Poster - Thur Eve - 46: The upcoming international code of practice for small static photon field dosimetry.

    Medical physics·2017
    Same author

    Specification of Dose Delivery in Radiation Therapy. Recommendations by the Nordic Association of Clinical Physics (NACP).

    Acta oncologica (Stockholm, Sweden)·2017
    Same author

    Monte Carlo calculated and experimentally determined output correction factors for small field detectors in Leksell Gamma Knife Perfexion beams.

    Physics in medicine and biology·2015
    Same author

    Fluence correction factors for graphite calorimetry in a low-energy clinical proton beam: I. Analytical and Monte Carlo simulations.

    Physics in medicine and biology·2013

    Area of Science:

    • Medical Physics
    • Radiation Oncology
    • Computational Physics

    Background:

    • Mean energy is crucial for therapeutic electron beam dosimetry.
    • Current models often assume constant mean energy across the beam, neglecting lateral variations.

    Purpose of the Study:

    • To analyze the variation of primary electron mean energy with depth and lateral position.
    • To compare Monte Carlo results with existing analytical expressions for mean energy determination.
    • To assess the impact of lateral energy variation on absorbed dose profiles.

    Main Methods:

    • Utilized the Monte Carlo method to simulate electron beam transport.
    • Analyzed the spatial distribution of mean electron energy.
    • Compared simulation data with analytical continuous slowing down expressions.

    Related Experiment Videos

    Main Results:

    • Monte Carlo simulations showed good agreement with analytical expressions for depth-dependent energy loss.
    • Calculated lateral variations in mean electron energy were observed.
    • Predicted differences in absorbed dose profiles due to lateral energy variation are less than 1%.

    Conclusions:

    • The continuous slowing down approximation adequately describes depth-dependent energy loss.
    • Lateral variations in mean electron energy have a negligible effect (<1%) on absorbed dose profiles.
    • Clinical dosimetry measurements using ionization chambers are unlikely to be significantly affected by lateral energy variations.